www.vishay.com For technical questions, contact: ind-modules@vishay.com
Document Number: 94395
2 Revision: 30-Apr-08
ST1230C..KP Series
Vishay High Power Products
Phase Control Thyristors
(Hockey PUK Version), 1745 A
ON-STATE CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum average on-state current
at heatsink temperature
I
T(AV)
180° conduction, half sine wave
double side (single side) cooled
1745 (700) A
55 (85) °C
Maximum RMS on-state current I
T(RMS)
DC at 25 °C heatsink temperature double side cooled 3200
A
Maximum peak, one-cycle
non-repetitive surge current
I
TSM
t = 10 ms
No voltage
reapplied
Sinusoidal half wave,
initial T
J
= T
J
maximum
33 500
t = 8.3 ms 35 100
t = 10 ms
100 % V
RRM
reapplied
28 200
t = 8.3 ms 29 500
Maximum I
2
t for fusing I
2
t
t = 10 ms
No voltage
reapplied
5615
kA
2
s
t = 8.3 ms 5126
t = 10 ms
100 % V
RRM
reapplied
3971
t = 8.3 ms 3625
Maximum I
2
√t for fusing I
2
√t t = 0.1 to 10 ms, no voltage reapplied 56 150 kA
2
√s
Low level value of threshold voltage V
T(TO)1
(16.7 % x π x I
T(AV)
< I < π x I
T(AV)
), T
J
= T
J
maximum 0.93
V
High level value of threshold voltage V
T(TO)2
(I > π x I
T(AV)
), T
J
= T
J
maximum 1.02
Low level value of on-state slope resistance r
t1
(16.7 % x π x I
T(AV)
< I < π x I
T(AV)
), T
J
= T
J
maximum 0.17
mΩ
High level value of on-state slope resistance r
t2
(I > π x I
T(AV)
), T
J
= T
J
maximum 0.16
Maximum on-state voltage V
TM
I
pk
= 4000 A, T
J
= T
J
maximum, t
p
= 10 ms sine pulse 1.62 V
Maximum holding current I
H
T
J
= 25 °C, anode supply 12 V resistive load
600
mA
Typical latching current I
L
1000
SWITCHING
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum non-repetitive rate of
rise of turned-on current
dI/dt
Gate drive 20 V, 20 Ω, t
r
≤ 1 µs
T
J
= T
J
maximum, anode voltage ≤ 80 % V
DRM
1000 A/µs
Typical delay time t
d
Gate current 1 A, dI
g
/dt = 1 A/µs
V
d
= 0.67 % V
DRM
, T
J
= 25 °C
1.9
µs
Typical turn-off time t
q
I
TM
= 550 A, T
J
= T
J
maximum, dI/dt = 40 A/µs,
V
R
= 50 V, dV/dt = 20 V/µs, gate 0 V 100 Ω, t
p
= 500 µs
200
BLOCKING
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum critical rate of rise of
off-state voltage
dV/dt T
J
= T
J
maximum linear to 80 % rated V
DRM
500 V/µs
Maximum peak reverse and
off-state leakage current
I
RRM
,
I
DRM
T
J
= T
J
maximum, rated V
DRM
/V
RRM
applied 100 mA
Komentarze do niniejszej Instrukcji